S3F80KB_AN_REV 0.00 (Preliminary Spec) IR REMOTE CONTROLLER
27
4 TEST METHOD
MCU MCU
Test board 1
Test board 2
Figure 10. Application Concept Diagram
4.1 IR TEST METHOD
1. Place two remote controllers to front each other
2. Configure test board 1 to transmission mode.
The initial mode is transmission mode after reset.
At the end of the learning mode, mode is go into transmission mode.
3. Configure test board 2 to reception mode.
Press Key(SW2 ~SW5) and next press key(SW6~17) to store IR data code
4. Press Key(Sw6 ~ Sw17) of the signal which want to transmit
5. Check 7-segment to confirm the transmission and reception is completed
To confirm, check test board 1 and test board 2's word displayed in 7-segment. If test board 1 and test
board 2's word is same, it's normal, otherwise it's abnormal. Check test board 2 displayed word in 7-
segment after press the key stored data code. If test board 1 and test board 2's word is same, it's normal,
otherwise it's abnormal.