19
7.3 Terminal Commands
The following is a summary of the Terminal Commands supported by the WC 1:
COMMAND PARAMETER DESCRIPTION RANGE UNITS
V1 Prepurge time 0-650.00 .01Sec.
V2 Arc start current 0-500 Amps
V3 Arc Start Wire feed speed 0-650 Ipm
V4 Arc Start delay time 0-650.00 .01 Sec.
V5 Ramp up Delay time 0-650.00 .01 Sec
V6 Run time current (Pulse Peak current) 0-650.00 Amps
V7 Run Time wire feed speed 0-650 Ipm
V8 Spot Weld Time (If Time=0 then Manual control) 0-650.00 .01 Sec.
V9 Percent Taper current 0-100 %
V10 Taper current delay time 0-650.00 .01 Sec.
V11 Ramp down delay time 0-650.00 .01 Sec.
V12 End current value 0-500 Amps
V13 End wire feed speed 0-650 Ipm
V14 End delay time 0-650.00 .01 Sec.
V15 Reverse wire speed time delay 0-650.00 Sec.
V16 Wire burn back delay time 0-650.00 .01 Sec.
V17 Post gas flow time delay 0-650.00 .01 Sec.
V18 Pulse current on time .001 – 65.000 .001 Sec.
V19 Pulse current off time .001 – 65.000 .001 Sec.
V20 Percent back ground current 0-100 %
V21 Jog wire feed speed 0-650 Ipm
Table 7 - Weld Process and Command Table