Universal Remote Control WC-1 Manual de Instalação Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 35
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
4
2.3 Remote Control Receptacle
The optional remote control receptacle provides a basic operational control interface to the WC 1
controller. The following is the pin-out and control function for the 9 pin receptacle.
PIN DESCRIPTION
1 +24 vdc @ 100 ma. Power Output
2 ESTOP – 24 VDC input
3 CYCLE START – 24 VDC input
4 INC – 24 VDC Input. Increase the current during the weld cycle
5 DEC – 24 VDC Input. Decreases the current during the weld cycle
6 CYCLE ON - 24 VDC Active low sinking (Pull-Down) output
7 CYCLE COMPLETE – 24 VDC Active Low sinking (Pull-Down) output
8 EARTH GROUND
9 READY – 24 vdc Active Low sinking (Pull-Down) output
Table 1 - WC 1 Remote Control Receptacle Pin-Out
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 34 35

Comentários a estes Manuais

Sem comentários